Rigid copper wires can be inserted without having to lift the lever.
- Better ergonomics
- Grooved surface for a better grip, for greater comfort of use
- Test openings for voltage testers
Application domain:
For all types of copper wire (single strand, multi-wire and fine). Controls for lamps, shutters, door and gate, intercom systems, pumps, vehicle electrical circuits, etc.
Features SeeHide
Number of drivers | 3 PCS |
Length x width x height | 20,5 x 18,5 x 10,5 mm |
Rigid wire cross section min./max. | 0,2-4 mm² |
Flexible wire cross section min./max. | 0,34-4 mm² |
Rated current | A 32 |
Stripping length | 11 mm |
Rated voltage | 450 V |
Maximum ambient temperature | 85 ° C |
T-mark according to EN 60998 | T85 |
Flammable | Self-extinguishing according to UL94 V2 |
Housing material | polycarbonate |
Color | Transparent |
Technical documentation SeeHide