Description See +Hide
The MW9660 is compliant for real estate diagnosis according to NF C16-600 and also for the electrician (NF C15-100 compliance).
Meets the tests of the NF C16-600 & NF C15-100 standards.
Measurements in accordance with EN61557.
Earth measurement with stakes (stakes supplied as standard).
Insulation measurement: 0-1GOhm under 100/250/500/1000V.
Ground loop measurement: 0-2kOhm.
Test of type A and AC 10mA/30mA/100mA/300mA/500mA/650mA differential circuit breakers, measurement of current and tripping time.
Voltage and frequency measurement, phase order indication.
Continuity measurement with buzzer.
Remote test probe (Optional).
Integrated magnetic support for "hands-free" work.
Features SeeHide
Sefram MW9660
Contains the Sefram MW9660 controller and all its accessories in its soft carrying case + the special NF C 16-600 help sheet written by TESTOON.
Optional. you can choose additional elements such as a personal protection kit (PPE) necessary for electrical interventions. a DDT/VAT voltage tester with LCD screen (for voltage absence checks and AC and DC voltage tests). the TESTOON Perchedia telescopic pole for "remote" continuity testing. an Enromalin reel for long-distance continuity tests...
The Sefram MW9660 tester is specially adapted for checking (NF C 15-100. NF C 16-600...) electrical installations. It will allow you to confidently carry out all the measurements required by the regulations in force.
• The backlit screen and its low weight facilitate on-site testing.
• Measures loop impedance without tripping RCDs
• Compact and light (~1 kg) for daily use
• Earth stake kit supplied as standard
• NF C 16-600 compliance. NF C15-100. EN 61557
Characteristics in accordance with NF C 16-600:
- Continuity measurement under 200 mA
- Fault loop impedance measurement with or without circuit breaker tripping
- Control of differential circuit breakers – ratings: 10. 30. 100. 300. 500. 1 A and 650mA
- Measurement of insulation resistance under a test voltage of 500 V
- Measurement of the resistance of earth electrodes using the stake method
- Voltage measurement
Additional functions:
- Voltage & frequency
- Checking Wiring Polarity
- RCD tripping times
- Tripping threshold (tripping current) of differential circuit breakers: ramp test
- RCD auto test sequence
- Control of type A and AC residual current circuit breakers
- Phase rotation order indicator
- Backlit display
- Voltage presence indicator
- Battery indicator
- Powered by 6 AA rechargeable NiMH batteries supplied (autonomy of approximately 20 hours). Mains charger supplied
- Works with standard alkaline batteries
- Integrated magnetic support for "hands-free" work
- Indication of test results by green (good) and red (bad) LEDs on the sides of the screen
- LCD display with integrated graphical help menu
- Safety CAT III 600V and CAT IV 300V
General documentation SeeHide