Contact the manufacturerYou have a project ?
Get a quotation




More images CheckHide
Description See +Hide
For forty years, VTI specialized in low-pressure ventilation systems: those used in buildings constructed before 1982 and their masonry ducts. SUPAIR'VENT® applies the same high standards to the next generation of buildings, such as apartment buildings built after 1982 and their metal ducts. Same expertise, two generations of buildings.
✅ Innovation lies in regulation.
The SUPAIR'VENT® unit is controlled by the VAR (Self-Regulating Speed) algorithm, patented by VTI : its integrated pressure sensors continuously adjust the motor speed to maintain the expected airflow, regardless of network conditions. Combined with an EC motor and a fan designed using digital simulation, this regulation system achieves a consumption of approximately 0,06 Wh per m³ of extracted air and quiet operation, even on long extraction ducts.
✅ Before construction begins, the technical study is conducted with the regional VTI specification manager or independently using MyVTI, VTI's free online configurator: building input, 2D rooftop network layout, and automatic sizing. The study delivers product selection, a schematic diagram, a projected electricity consumption estimate, data for RT calculations, and a detailed quote, including a standard technical specifications document, bill of quantities, and pre-filled energy efficiency certificate (CEE) forms. The VTI teams then validate the final solution with the client and prepare the 2D installation technical file before manufacturing begins.
✅ On-site, shipping takes place within 48 to 72 hours of order confirmation. The range is designed for roofs and difficult access areas : single-unit units or kits (DuoKit, MultiKit) for on-site assembly with a single tool, adjustable feet, and suspension handles. Upon commissioning, VTI technicians adjust and configure the units on-site, measure negative pressure and flow rates on a sample of dwellings, and provide a commissioning report. Installers receive training in installation, configuration, and diagnostics at the VTI Academy, a Qualiopi-certified training center.
✅ Two versions cover renovation configurations.
The range includes two versions, available in Auto, Hygro A, and Hygro B, both with CSTB Technical Approval and eligible for Energy Savings Certificates (CEE) in their humidity-controlled versions. ➡️ SUPAIR'VENT®, QB37 certified thanks to its VAR regulation, is suitable for complex and high-rise construction sites.
➡️ SUPAIR'VENT® COMPACT, without a plenum, is designed for intermediate buildings (3 to 5 stories) with short ductwork. Within the same building complex, the range can be combined with VTI low-pressure solutions: a single manufacturer for buildings constructed before and after 1982.
✅ On the same site, the range can be combined with VTI low pressure solutions : a single manufacturer for buildings before and after 1982. Designed by the VTI design office and manufactured in Frontignan (Hérault), it is supported by the same teams as the low pressure: regional specification managers, assisted commissioning, VTI Academy training, after-sales service.
VTI #green air
Characteristics CheckHide
- Type : High pressure single flow VMC, collective extraction
- Application: Renovation of multi-family residential buildings constructed after 1982 (galvanized steel pipes), renovations where low pressure is no longer suitable, building extensions, mixed projects with VTI low-pressure solutions
- Debits: 8 sizes, from 700 to 8000 m³/h (SPV 700 to SPV 8000)
- Versions: Auto, Hygro A, Hygro B
- Installation: roof terrace, attic or technical room; monobloc box, DuoKit, MultiKit 1 or MultiKit 2
- Motorization and regulation: EC motor; patented VAR regulation with integrated pressure sensors (SUPAIR'VENT® boxes only)
- Consumption: approximately 0,06 Wh/m³ of extracted air; energy class B (building type R+4, zone H1a)
- Fire safety : Category C4, 400 °C for 30 minutes (ref. EFR-23-003082)
- Certifications for the product range: CSTB Technical Opinion No. 14.5/23-2315 for Hygro A and B versions of SUPAIR'VENT® and SUPAIR'VENT® COMPACT; eligible for Energy Savings Certificates (humidity-controlled versions); ErP Ready (EU Regulation 1253/2014)
- Certifications specific to SUPAIR'VENT®: QB37 (VAR regulation); Eurovent 77/1-CHY6-2315
- Deadline : Shipping within 48 to 72 hours after order confirmation
- MyVTI prescribing tool: cFree online configurator, low pressure and VMC; 2D layout of the roof network and automatic sizing; quotes, standard technical specifications, detailed price schedule, pre-filled CEE forms, consumption data and files for integration with RT software; project history in the user area.
- Training: VTI Academy, Qualiopi certified, 7 hours (installation, configuration, commissioning, diagnostics, troubleshooting)
- Connectivity: Optional Infobox Revolution® (monitoring, alerts, consumption tracking, Modbus interface for BMS)
- Manufacturing: France, Frontignan (34)
General documentation CheckHide
Technical documentation CheckHide
Videos CheckHide

VTI - Webinar: Discover SUPAIR'VENT®, the new high-pressure ventilation solution from VTI
VideoVisit
SUPAIR'VENT, NEW HIGH-PRESSURE VENTILATION SOLUTION
VideoVisit
SUPAIR'VENT: Designed to last, engineered to breathe.
VideoVisit
- Ventilation
- #Ventilation
- #VMC
- #High pressure
- #Renovation
- #CollectiveHousing









